{"id":19564,"date":"2022-08-17T10:39:25","date_gmt":"2022-08-17T10:39:25","guid":{"rendered":"https:\/\/tthcompany.ma\/?post_type=product&#038;p=19564"},"modified":"2023-09-26T14:56:16","modified_gmt":"2023-09-26T14:56:16","slug":"pfs5452-48gt4xf-400","status":"publish","type":"product","link":"https:\/\/tthcompany.ma\/index.php\/product\/pfs5452-48gt4xf-400\/","title":{"rendered":"PFS5452-48GT4XF-400"},"content":{"rendered":"<table id=\"table001\" class=\"NEW-TABLE TableOverride-1 tab-drag\">\n<tbody>\n<tr>\n<td colspan=\"60\">Performance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Couche<\/td>\n<td colspan=\"42\">Couche 2+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">G\u00e9r\u00e9<\/td>\n<td colspan=\"42\">Oui<\/td>\n<\/tr>\n<tr>\n<td colspan=\"60\">Mat\u00e9riel<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Alimentation standard<\/td>\n<td colspan=\"42\">Oui<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">PoE<\/td>\n<td colspan=\"42\">Oui<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Port Ethernet<\/td>\n<td colspan=\"42\">48<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Port optique<\/td>\n<td colspan=\"42\">4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">D\u00e9bit du port Ethernet<\/td>\n<td colspan=\"42\">1 Gbit\/s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Taux de port optique<\/td>\n<td colspan=\"42\">10 Gbit\/s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Modulaire\/Fixe<\/td>\n<td colspan=\"42\">Fix\u00e9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">D\u00e9bogage<\/td>\n<td colspan=\"42\">D\u00e9bogage<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Source de courant<\/td>\n<td colspan=\"42\">100\u00a0V\u2013240\u00a0V CA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Temp\u00e9rature de fonctionnement<\/td>\n<td colspan=\"42\">0\u00b0C \u00e0 45\u00b0C (32\u00b0F \u00e0 113\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">humidit\u00e9 d&#8217;exploitation<\/td>\n<td colspan=\"42\">10 % \u00e0 90 %<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Temp\u00e9rature de stockage<\/td>\n<td colspan=\"42\">\u201340\u00b0C \u00e0 70\u00b0C (\u201340\u00b0F \u00e0 158\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Humidit\u00e9 de stockage<\/td>\n<td colspan=\"42\">5%-90%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Consommation d&#8217;\u00e9nergie<\/td>\n<td colspan=\"42\">Au ralenti : 39,7 W<br \/>\nPleine charge : 473,7 W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"60\">Performance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Capacit\u00e9 de commutation<\/td>\n<td colspan=\"42\">176 Gbit\/s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Taux de transfert de paquets<\/td>\n<td colspan=\"42\">130,944 Mpps<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">M\u00e9moire tampon de paquets<\/td>\n<td colspan=\"42\">12 Mbits<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Taille de la table MAC<\/td>\n<td colspan=\"42\">16K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Ports du routeur<\/td>\n<td colspan=\"42\">256<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Tableau de routage IPv4<\/td>\n<td colspan=\"42\">511<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">File d&#8217;attente QoS<\/td>\n<td colspan=\"42\">8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">R\u00e8gles de classification<\/td>\n<td colspan=\"42\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Montant de la liste de contr\u00f4le d&#8217;acc\u00e8s IPv4<\/td>\n<td colspan=\"42\">128<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Granularit\u00e9 de la limite de trafic<\/td>\n<td colspan=\"42\">64K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Granularit\u00e9 de la limite de trafic ACL<\/td>\n<td colspan=\"42\">64K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Conformit\u00e9 aux normes<\/td>\n<td colspan=\"42\">IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3az, IEEE 802.3ae, IEEE802.3x, IEEE802.3z, IEEE802.3ad, IEEE802.1P, IEEE802.1Q, IEEE802.3af, IEEE802.3at<\/td>\n<\/tr>\n<tr>\n<td colspan=\"60\">PoE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Norme PoE<\/td>\n<td colspan=\"42\">IEEE802.3af, IEEE802.3at<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Budget PoE<\/td>\n<td colspan=\"42\">400W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Gestion PoE<\/td>\n<td colspan=\"42\">Oui<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Affectation des broches PoE<\/td>\n<td colspan=\"42\">1\/2(+), 3\/6(-)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Transmission PoE longue distance<\/td>\n<td colspan=\"42\">Non<\/td>\n<\/tr>\n<tr>\n<td colspan=\"60\">Fonction<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">IPv4<\/td>\n<td colspan=\"42\">Proxy ARP\u00a0;<br \/>\nRelais DHCP\u00a0;<br \/>\nServeur DHCP;<br \/>\nRoute statique\u00a0;<br \/>\nD\u00c9CHIRURE;<br \/>\nOSPF<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">IPv6<\/td>\n<td colspan=\"42\">Prise en charge d&#8217;ICMPv6<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">LCA<\/td>\n<td colspan=\"42\">Oui<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Cadre g\u00e9ant<\/td>\n<td colspan=\"42\">12 Ko<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">ARP<\/td>\n<td colspan=\"42\">\u00c9l\u00e9ments de table statiques\u00a0;<br \/>\nARP gratuit<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Tableau d&#8217;adresses MAC<\/td>\n<td colspan=\"42\">16K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Protocole Spanning Tree<\/td>\n<td colspan=\"42\">STP, RSTP, MSTP, ERPS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">VLAN<\/td>\n<td colspan=\"42\">base sur MAC\/protocole\/sous-r\u00e9seau IP\/Strat\u00e9gie\/port VLAN\u00a0;<br \/>\ntunnel Dot1q\u00a0;<br \/>\nGVRP\u00a0;<br \/>\ntraduction VLAN\u00a0;<br \/>\nApprentissage et vieillissement automatiques de l&#8217;adresse MAC\u00a0;<br \/>\nfiltre d&#8217;adresse MAC source<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Contr\u00f4le de flux<\/td>\n<td colspan=\"42\">Prise en charge du contr\u00f4le de flux bas\u00e9 sur IEEE802.3X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Agr\u00e9gation de liens<\/td>\n<td colspan=\"42\">Prise en charge IEEE 802.3ad (agr\u00e9gation de liens)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Mise en miroir des ports<\/td>\n<td colspan=\"42\">Oui<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Multidiffusion<\/td>\n<td colspan=\"42\">Multidiffusion<br \/>\nIPv6 de\u00a0surveillance IGMP\u00a0;\u00a0MLD<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">DHCP<\/td>\n<td colspan=\"42\">relais DHCP\u00a0;<br \/>\nServeur DHCP;<br \/>\nSurveillance DHCP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">S\u00e9curit\u00e9<\/td>\n<td colspan=\"42\">LCA\u00a0;<br \/>\n802.1x, authentification Radius\u00a0;<br \/>\nProtection contre les attaques DoS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">QoS<\/td>\n<td colspan=\"42\">SPQ, WRR, SP+WRR, WFQ, SP+WFQ<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Taille de la table ARP<\/td>\n<td colspan=\"42\">8K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Montant VLAN<\/td>\n<td colspan=\"42\">4K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Table de routage<\/td>\n<td colspan=\"42\">256<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Entretien du syst\u00e8me<\/td>\n<td colspan=\"42\">chargement et t\u00e9l\u00e9chargement du fichier de configuration\u00a0;<br \/>\nt\u00e9l\u00e9chargement du package de mise \u00e0 niveau\u00a0;<br \/>\njournal du syst\u00e8me<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Gestion d&#8217;appareils<\/td>\n<td colspan=\"42\">La toile;<br \/>\nTelnet\u00a0;<br \/>\nCLI\u00a0;<br \/>\nSNMP V1\/V2C\/V3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"60\">G\u00e9n\u00e9ral<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">DES<\/td>\n<td colspan=\"42\">D\u00e9charge dans l&#8217;air : 2kV<br \/>\nD\u00e9charge au contact : 1kV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">\u00c0 l&#8217;\u00e9preuve du tonnerre<\/td>\n<td colspan=\"42\">Mode commun : \u00b12kV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Poids net<\/td>\n<td colspan=\"42\">4,5 kg (9,92 livres)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Poids brut<\/td>\n<td colspan=\"42\">4,8 kg (10,58 livres)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">dimensions du produit<\/td>\n<td colspan=\"42\">440 mm \u00d7 330 mm \u00d7 44,5 mm (17,32&#8243; \u00d7 12,99&#8243; \u00d7 1,75&#8243;)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"18\">Dimensions de l&#8217;emballage<\/td>\n<td colspan=\"42\">494 mm \u00d7 482 mm \u00d7 113 mm (19,45&#8243; \u00d7 18,98&#8243; \u00d7 4,45&#8243;)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h3 class=\"text\" data-gtm-vis-first-on-screen-10552706_217=\"514\" data-gtm-vis-recent-on-screen-10552706_181=\"518\" data-gtm-vis-first-on-screen-10552706_181=\"518\" data-gtm-vis-total-visible-time-10552706_181=\"100\" data-gtm-vis-has-fired-10552706_181=\"1\" data-gtm-vis-first-on-screen-10552706_192=\"520\" data-gtm-vis-first-on-screen-10552706_184=\"523\" data-gtm-vis-recent-on-screen-10552706_195=\"528\" data-gtm-vis-first-on-screen-10552706_195=\"528\" data-gtm-vis-total-visible-time-10552706_195=\"100\" data-gtm-vis-has-fired-10552706_195=\"1\" data-gtm-vis-first-on-screen-10552706_193=\"529\" data-gtm-vis-first-on-screen-10552706_196=\"531\" data-gtm-vis-first-on-screen-10552706_194=\"538\" data-gtm-vis-recent-on-screen-10552706_217=\"1423371\" data-gtm-vis-total-visible-time-10552706_217=\"100\" data-gtm-vis-has-fired-10552706_217=\"1\" data-gtm-vis-recent-on-screen-10552706_193=\"1423372\" data-gtm-vis-total-visible-time-10552706_193=\"100\" data-gtm-vis-has-fired-10552706_193=\"1\" data-gtm-vis-recent-on-screen-10552706_194=\"1423373\" data-gtm-vis-total-visible-time-10552706_194=\"100\" data-gtm-vis-has-fired-10552706_194=\"1\" data-gtm-vis-recent-on-screen-10552706_192=\"1423373\" data-gtm-vis-total-visible-time-10552706_192=\"100\" data-gtm-vis-has-fired-10552706_192=\"1\" data-gtm-vis-recent-on-screen-10552706_196=\"1423377\" data-gtm-vis-total-visible-time-10552706_196=\"100\" data-gtm-vis-has-fired-10552706_196=\"1\" data-gtm-vis-recent-on-screen-10552706_184=\"1423377\" data-gtm-vis-total-visible-time-10552706_184=\"100\" data-gtm-vis-has-fired-10552706_184=\"1\"><span style=\"font-size: 12pt;\"><strong>Commutateur PoE g\u00e9r\u00e9 Gigabit \u00e0 48 ports Dahua<\/strong><\/span><\/h3>\n<div data-v-5fe8c490=\"\">\n<ul>\n<li>\u00a0Prise en charge de la route statique, r\u00e9alisant le transfert de couche 3 pour les donn\u00e9es du r\u00e9seau.<\/li>\n<li>Prise en charge de la pile virtuelle, virtualisation de plusieurs commutateurs en un seul pour am\u00e9liorer la fiabilit\u00e9 et simplifier la configuration et la gestion.<\/li>\n<li>Prise en charge de la liaison montante 10 Gbps avec 4 ports, r\u00e9alisant une transmission de donn\u00e9es volumineuses sans d\u00e9calage.<\/li>\n<li>Prise en charge de divers types de gestion.<\/li>\n<\/ul>\n<\/div>\n","protected":false},"featured_media":19619,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_cat":[330],"product_tag":[1093],"class_list":["post-19564","product","type-product","status-publish","has-post-thumbnail","product_cat-switch-poe","product_tag-onstuck","ts_product_brand-dahua","first","instock","shipping-taxable","purchasable","product-type-simple","add-to-wishlist-after_add_to_cart"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/product\/19564","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/comments?post=19564"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/media\/19619"}],"wp:attachment":[{"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/media?parent=19564"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/product_cat?post=19564"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tthcompany.ma\/index.php\/wp-json\/wp\/v2\/product_tag?post=19564"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}